Customization: | Available |
---|---|
Type: | High Frequency Ultrasonic Sensor |
Output Signal Type: | Switch Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical data |
General Specifications |
Sensing distance 30…400mm |
Adjustment range 50…400mm |
Unusable area 0…30mm |
Standard target plate 100mm×100mm |
Transducer frequency About 310kHz |
Response delay About 50ms |
Indicators/Operating means |
LED blue Power on |
LED yellow indication of the switching state Flashing:program function object detected |
LED red permanently red: Error Red,flashing:program function,object not detected |
Electrical specifications |
Operating voltage UB 10…30VDC,ripple10%ss |
No-load supply current ≤30mA |
Input |
Input type 1 TEACH-IN input Operating distance A1:-UB…+1V,operating distanceA2:+6… + UB Input impedance:>4.7KΩ TEACH-IN programmable pulse :≥1S |
Output |
Output type 1 switch output E5,PNP NO/NC, programmable |
Rated operational current 100mA,short-circuit/overload protected |
Default setting Switching point A1:70mm Switching point A2: 800mm |
Voltage drop ≤ 3V |
Repeat accuracy ≤ 1% |
Switching frequency f ≤ 8 HZ |
Range hysteresis H 1% of the set operating distance |
Temperature influence ± 1.5% of full-scale value |
Ambient conditions |
Ambient temperature -25…70ºC(248...343K) |
Storage temperature -40…85ºC(233...358K) |
Mechanical specifications |
Protection grade IP67 |
Connection V1 connector(M12×1),4-pin |
Material Housing brass,nickel-plated |
Transducer epoxy resin/hollow glass sphere mixture; foam polyurethane,cover PBT |
Weight 25g |
Compliance with standards and di |
Standard conformity EN 60947-5-2:2007 IEC 60947-5-2:2007 |
Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 mins when power
on. If want to change the switching point, the user can only setting the request distance after power restart.
TEACH-IN window mode,normally-open function -Set target to near switching point -TEACH-IN switching point A1 with - UB -Set target to far switching point -TEACH-IN switching point A2 with + UB | ||
TEACH-IN window mode,normally-closed function -Set target to near switching point -TEACH-IN switching point A2 with + UB -Set target to far switching point -TEACH-IN switching point A1 with - UB |
TEACH-IN switching point, normally-open function -Set target to near switching point -TEACH-IN switching point A2 with + UB -Cover sensor with hand or remove all objects from sensing range -TEACH-IN switching point A1 with - UB | |||
TEACH-IN switching point, normally-closed function -Set target to near switching point -TEACH-IN switching point A1 with - UB -Cover sensor with hand or remove all objects from sensing range -TEACH-IN switching point A2 with + UB | |||
TEACH-IN detection of objects presence -Cover sensor with hand or remove all objects from sensing range -TEACH-IN switching point A1 with - UB -TEACH-IN switching point A2 with + UB | |||
Default setting of switching point A1=blind range,A2=nominal distance | |||
LED displays | |||
Displays in dependence on operating mode | Red LED | Yellow LED | |
TEACH-IN switching point Object detected No object detected Object uncertain(TEACH-IN invalid) | off flashes On | flashes off off | |
Normal operation | off | Switching state | |
Fault | on | Previous state |
Installation conditions
If the sensor is installed at the environment temperature fall below 0ºC,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.