Stord Manufacturer Hot Selling Analog Output Ultrasonic Sensor Ce Approval Ub500-18GM-U-V1

Product Details
Customization: Available
Type: High Frequency Ultrasonic Sensor
Output Signal Type: Analog Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
to see all verified strength labels (25)
Find Similar Products

Basic Info.

Model NO.
UB500-18GM75-U-V1
Sensitivity
High
Probe Type
Straight Probe
Measuring Medium
Liquid
IP Rating
IP55
Certification
CE
Customized
Customized
Output
Analog Sensor
Usage
Position Sensor
Theory
Ultrasonic Sensor
Material
Mixture
Transport Package
Ultrasonic Sensor Special Box
Trademark
STORD
Origin
China

Product Description

Technical data
General Specifications
Sensing distance                     30…500mm
Adjustment range                        50…500mm
Unusable area                             0…30mm
Standard target plate                    100mm×100mm
Transducer frequency                   About 380 kHz
Response delay                            About 50ms
Indicators/Operating means      
LED blue                                    Power on
LED yellow                             indication of the switching state
                                              Flashing:program function object detected
LED red                     permanently red: Error Red,flashing:program function,object not detected
Electrical specifications
Operating voltage UB                   10…30VDC,ripple10%ss
No-load supply current                ≤45mA
Output
Output type                          1 analogue output 0…10V
Resolution                                  0.11mm at max.sensing range
Deviation of the characteristic
curve                          ±1% of full-scale value
Repeat accuracy               ±0.1% of full-scale value
Load impedance                    >1k Ohm
Temperature influence                  ±1.5% of full-scale value
Ambient conditions
Ambient temperature             -25…70ºC
Storage temperature                     -40…85ºC
Mechanical specifications
 
Protection grade                          IP67
Connection                              Connector M12x1,4-PIN
Material
   Housing                             brass,nickel-plated
Transducer                   epoxy resin/hollow glass sphere mixture;
                            Polyurethane foam
Weight                                    60g






External synchronization
The sensor can be synchronised by the external application of a square wave voltage. A synchronisation pulse at the synchronisation
input starts a measuring cycle. The pulse must have a duration greater than 100 μs. The measuring cycle starts with
the falling edge of a synchronisation pulse. A low level > 1 s or an open synchronisation input will result in the normal operation
of the sensor. A high level at the synchronisation input disables the sensor. Two operating modes are available:
1. Multiple sensors can be controlled by the same synchronisation signal. The sensors are synchronised.
2. The synchronisation pulses are sent cyclically to individual sensors. The sensors operate in multiplex mode.
 
Internal synchronization
The synchronisation connections of up to 5 sensors capable of internal synchronisation are connected to one another. When
power is applied, these sensors will operate in multiplex mode.
The response delay increases according to the number of sensors to be synchronised. Synchronisation cannot be performed
during TEACH-IN and vice versa. The sensors must be operated in an unsynchronised manner to teach the evaluation limits.
 
Note:
If the option for synchronisation is not used, the synchronisation input has to be connected to ground (0V) or the sensor has to
be operated via a V1 cable connector (4-pin).

Adjusting the evaluation limits
The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply
voltage -UB or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs
indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught
with -UB, A2 with +UB.
Two different output functions can be set:
1. Analogue value increases with rising distance to object (rising ramp)
2. Analogue value falls with rising distance to object (falling ramp)
Evaluation limits may only be specified within the first 5 minutes after
Power on. To modify the evaluation limits later,
the user may specify the desired values only after a new Power On.

TEACH-IN rising ramp (A2 > A1)
- Position object at lower evaluation limit
- TEACH-IN lower limit A1 with - UB
- Position object at upper evaluation limit
- TEACH-IN upper limit A2 with + UB
 

TEACH-IN falling ramp (A1 > A2):
- Position object at lower evaluation limit
- TEACH-IN lower limit A2 with + UB
- Position object at upper evaluation limit
- TEACH-IN upper limit A1 with - UB
 
Default setting
A1: unusable area
A2: nominal sensing range
Mode of operation: rising ramp


Pictures show 















 